ACT Logo
|ADVANCED COOLING TECHNOLOGIES
contact
  • Thermal Solutions
    • Passive Thermal Solutions
      • Heat Pipes
        • HiK Plates­™/ Heat Pipe Assemblies
        • Pulsating Heat Pipes
        • Vapor Chambers
        • High Temperature Heat Pipes
      • Loop Thermosyphons
      • Phase Change Based Solutions
        • PCM Heat Sinks
      • Custom Cold Plates
    • Active Thermal Management Solutions
      • Liquid Cooling
      • Pumped Two-Phase
      • Liquid-Air HX
      • Tekgard® ECUs
      • Tekgard® Chillers
    • Embedded Computing Solutions
      • ICE-Lok®
      • VME/ VPX Card Frames
      • Conduction Cooled Chassis
      • Liquid Cooled Chassis
    • Enclosure Cooling Products
      • HSC (Heat Sink Coolers)
      • HPC (Heat Pipe Coolers)
      • TEC (Thermoeletric Coolers)
      • VCC (Vapor Compression Coolers)
      • Enclosure Cooling Selection Tool
    • HVAC Energy Recovery
      • AAHX
      • WAHX
    • Space Thermal Control
      • Constant Conductance Heat Pipes
      • Variable Conductance Heat Pipes
      • Space Copper-Water Heat Pipes
      • Loop Heat Pipes
      • Space VPX
      • Liquid Cooling
  • Engineering Services
    • Research & Development
      • Team & Value Add
      • Emerging Technology
      • Technical Papers
      • Other Research Interests
    • Product Development
    • Manufacturing
    • Lifecycle Management
  • Industries
    • Space
    • Defense
    • Energy
    • HVAC Energy Recovery
    • Medical
    • Other
  • Resources
    • Blog
    • Calculators & Selection Tools
      • AAHX Selection Tool
      • Enclosure Cooling Selection Tool
      • Heat Pipe Calculator
      • PCM Calculator
      • WAHX Selection Tool
    • Publications
      • Published Articles
      • Patents
      • Technical Papers
    • Learning Center
      • Heat Pipe Learning Center
      • Pumped Two-Phase Learning Center
      • PCM Learning Center
      • HVAC Learning Center
      • Videos
      • eBooks
      • Brochures
      • Case Studies
      • Webinars
    • Find your Rep
  • About
    • Careers
    • Events
    • News
  • Contact
  • Thermal Solutions
    • Passive Thermal Solutions
      • Heat Pipes
        • HiK Plates­™/ Heat Pipe Assemblies
        • Pulsating Heat Pipes
        • Vapor Chambers
        • High Temperature Heat Pipes
      • Loop Thermosyphons
      • Phase Change Based Solutions
        • PCM Heat Sinks
      • Custom Cold Plates
    • Active Thermal Management Solutions
      • Liquid Cooling
      • Pumped Two-Phase
      • Liquid-Air HX
      • Tekgard® ECUs
      • Tekgard® Chillers
    • Embedded Computing Solutions
      • ICE-Lok®
      • VME/ VPX Card Frames
      • Conduction Cooled Chassis
      • Liquid Cooled Chassis
    • Enclosure Cooling Products
      • HSC (Heat Sink Coolers)
      • HPC (Heat Pipe Coolers)
      • TEC (Thermoeletric Coolers)
      • VCC (Vapor Compression Coolers)
      • Enclosure Cooling Selection Tool
    • HVAC Energy Recovery
      • AAHX
      • WAHX
    • Space Thermal Control
      • Constant Conductance Heat Pipes
      • Variable Conductance Heat Pipes
      • Space Copper-Water Heat Pipes
      • Loop Heat Pipes
      • Space VPX
      • Liquid Cooling
  • Engineering Services
    • Research & Development
      • Team & Value Add
      • Emerging Technology
      • Technical Papers
      • Other Research Interests
    • Product Development
    • Manufacturing
    • Lifecycle Management
  • Industries
    • Space
    • Defense
    • Energy
    • HVAC Energy Recovery
    • Medical
    • Other
  • Resources
    • Blog
    • Calculators & Selection Tools
      • AAHX Selection Tool
      • Enclosure Cooling Selection Tool
      • Heat Pipe Calculator
      • PCM Calculator
      • WAHX Selection Tool
    • Publications
      • Published Articles
      • Patents
      • Technical Papers
    • Learning Center
      • Heat Pipe Learning Center
      • Pumped Two-Phase Learning Center
      • PCM Learning Center
      • HVAC Learning Center
      • Videos
      • eBooks
      • Brochures
      • Case Studies
      • Webinars
    • Find your Rep
  • About
    • Careers
    • Events
    • News
  • Contact
  • Heat Pipes
  • Loop Thermosyphons
  • Phase Change Based Solutions
  • Custom Cold Plates
Thermal Solutions | Passive Thermal Solutions | Loop Thermosyphons
Loop Thermosyphons

WHAT IS A LOOP THERMOSYPHON?

A Loop Thermosyphon (LTS) is an ideal solution for any system that can leverage gravity assist fluid return. LTS are routinely found in Power Electronics applications where customers mount IGBTs and other high-power density devices directly to an evaporator plate and have the ability to remotely locate the condenser or heat sink above the components. ACT systems are fielded in a variety of industries including medical, energy/utility, automation, and HVAC systems.

The principle operation is similar to a heat pipe or thermosyphon where heat generated by components causes liquid within the attached cold plates to evaporate.  The expansion of this fluid as it changes phase from liquid to vapor creates a stirring motion that increases convection and subsequently, heat transfer efficiency. The system takes advantage of the latent heat of the fluid which allows for such high heat transfer rates. A Loop Thermosyphon can move larger amounts of heat compared to a similar-sized heat pipe or thermosyphon because there is no counterflow (liquid and vapor moving in opposing directions). The “loop” aspect makes this possible by designing a discrete vapor line to the heat sink, condensing within the heatsink, and liquid returning down a separate fluid line.

A loop thermosyphon is a scalable technology, with products built from less than 100W to upward of 75,000W. It’s an ideal choice for electronics and Power Electronics applications because of its passive operation, di-electric working fluid options, and high performance. Geometric design flexibility is also critical to most system engineers. Loop thermosyphons can move heat very large distances and can incorporate important features on the evaporator, condenser and fluid lines to allow for easy integration.

A few past projects tailored to our customer’s needs:

Power Electronics Cooler

  • Industry: Power Conversion
  • Power: 5-15 kW
  • Key Features: Patent-pending evaporator plate to allow for direct mount of multiple IGBTs on both sides. Di-electric fluid for electrical isolation.

Flexible Line, IGBT Cooler

  • Industry: Industrial Power Electronics
  • Power: 5-15 kW
  • Key Features: Dielectric, flexible coolant lines for remote mounting of condenser. Direct mount, patent-pending custom evaporator design. Multiple condenser configurations available

Loop Thermosyphon for a Medical Application

  • Power: ~1000W
  • Key Features: All aluminum design; High heat flux evaporator design (~40 W/cm2); eliminating the need for a chiller

Single IGBT Cooler

  • Application: Solid-state transformer
  • Power: ~1000W
  • Key Features: All Aluminum construction; Patent pending custom evaporator design

HVAC Heat Exchangers

  • Industry HVAC Energy Recovery
  • Power: Scalable > 100kW
  • Configurations:
    • WAHX; AAHX; Split Loop Thermosyphon
TALK WITH OUR ENGINEERS
Tell us about your project, the more details the better. That way we know which team to get you started with. We will reach out to get a meeting scheduled and get you on your way to solving this thermal challenge.
Contact ACT Today
Top Up facing arrow in a square
Page Index
  1. WHAT IS A LOOP THERMOSYPHON?
  2. A few past projects tailored to our customer's needs:
    1. Power Electronics Cooler
    2. Flexible Line, IGBT Cooler
    3. Loop Thermosyphon for a Medical Application
Related Resources
Heat Pipe Learning Center Icon for Heat Pipe Learning Center Webinar: High Performance Thermal Solutions Icon for Webinar: High Performance Thermal Solutions Loop Thermosyphon Feature Article Icon for Loop Thermosyphon Feature Article High Heat Flux Loop Thermosyphon for Laboratory Measurement Systems Icon for High Heat Flux Loop Thermosyphon for Laboratory Measurement Systems
ACT Quality White arrow in white square Contact ACT White arrow in white square Find your Rep White arrow in white square
ACT Logo
Advanced Cooling Technologies, Inc.
1046 New Holland Avenue
Lancaster, Pennsylvania 17601, USA
(717) 295-6061 contact
linkedin youtube twitter facebook
  • sitemap
  • privacy policy
  • terms & conditions
  • ISO9001 & AS9100 CERTIFIED, ITAR REGISTERED

Copyright 2023. All rights reserved.