ACT Logo
|ADVANCED COOLING TECHNOLOGIES
0
Cart Icon
Contact Us
  • Thermal Solutions
    • Passive Thermal Solutions
      • Heat Pipes
        • HiK Plates­™/ Heat Pipe Assemblies
        • Pulsating Heat Pipes
        • Vapor Chambers
        • High Temperature Heat Pipes
      • Loop Thermosyphon
      • Phase Change Based Solutions
        • PCM Heat Sinks
      • Liquid Cold Plates
    • Enclosure Cooling Products
      • HSC (Heat Sink Coolers)
      • HPC (Heat Pipe Coolers)
      • TEC (Thermoelectric Coolers)
      • VCC (Vapor Compression Coolers)
      • Enclosure Cooling Selection Tool
    • Space Thermal Control
      • Constant Conductance Heat Pipes
      • Variable Conductance Heat Pipes
      • Space Copper-Water Heat Pipes
      • Loop Heat Pipes
      • Space VPX
      • Liquid Cooling
    • Active Thermal Management Solutions
      • Liquid Cooling
      • Pumped Two-Phase
      • Liquid-Air HX
      • Tekgard® ECUs
      • Vaphtek™ ECU
      • Tekgard® Chillers
    • Embedded Computing Solutions
      • ICE-Lok®
      • VME/ VPX Card Frames
      • Conduction Cooled Chassis
      • Liquid Cooled Chassis
    • HVAC Energy Recovery
      • AAHX
      • WAHX
  • Engineering Services
    • Research & Development
      • Our Research & Development Team
      • Emerging Technology
      • Technical Papers
      • Other Research Interests
    • Product Development
    • Space Thermal & Structural Analysis
    • Manufacturing
    • Lifecycle Management
  • Industries
    • Energy
      • Wind Energy
      • Nuclear Energy
      • Power Conversion
      • Energy Storage
      • HVAC Energy Recovery
    • Space
    • HVAC Energy Recovery
    • Defense
    • Medical
    • Data Centers
    • Other
  • Resources
    • Blog
    • Calculators & Selection Tools
      • AAHX Selection Tool
      • Enclosure Cooling Selection Tool
      • Heat Pipe Calculator
      • PCM Calculator
      • WAHX Selection Tool
    • Publications
      • Published Articles
      • Patents
      • Technical Papers
    • Learning Center
      • Heat Pipe Learning Center
      • Pumped Two-Phase Learning Center
      • PCM Learning Center
      • HVAC Learning Center
      • Videos
      • eBooks
      • Brochures
      • Case Studies
      • Webinars
    • Find your Rep
  • Shop
    • Sealed Enclosure Coolers
    • Heat Pipe Coolers
      • Heat Pipe Cooler Accessories
    • Heat Sink Coolers
      • Heat Sink Cooler Accessories
    • Thermoelectric Coolers
    • Vapor Compression Coolers
  • About
    • Careers
    • Events
    • News
    • Sustainability
    • ACT Leadership
  • Contact
  • Thermal Solutions
    • Passive Thermal Solutions
      • Heat Pipes
        • HiK Plates­™/ Heat Pipe Assemblies
        • Pulsating Heat Pipes
        • Vapor Chambers
        • High Temperature Heat Pipes
      • Loop Thermosyphon
      • Phase Change Based Solutions
        • PCM Heat Sinks
      • Liquid Cold Plates
    • Enclosure Cooling Products
      • HSC (Heat Sink Coolers)
      • HPC (Heat Pipe Coolers)
      • TEC (Thermoelectric Coolers)
      • VCC (Vapor Compression Coolers)
      • Enclosure Cooling Selection Tool
    • Space Thermal Control
      • Constant Conductance Heat Pipes
      • Variable Conductance Heat Pipes
      • Space Copper-Water Heat Pipes
      • Loop Heat Pipes
      • Space VPX
      • Liquid Cooling
    • Active Thermal Management Solutions
      • Liquid Cooling
      • Pumped Two-Phase
      • Liquid-Air HX
      • Tekgard® ECUs
      • Vaphtek™ ECU
      • Tekgard® Chillers
    • Embedded Computing Solutions
      • ICE-Lok®
      • VME/ VPX Card Frames
      • Conduction Cooled Chassis
      • Liquid Cooled Chassis
    • HVAC Energy Recovery
      • AAHX
      • WAHX
  • Engineering Services
    • Research & Development
      • Our Research & Development Team
      • Emerging Technology
      • Technical Papers
      • Other Research Interests
    • Product Development
    • Space Thermal & Structural Analysis
    • Manufacturing
    • Lifecycle Management
  • Industries
    • Energy
      • Wind Energy
      • Nuclear Energy
      • Power Conversion
      • Energy Storage
      • HVAC Energy Recovery
    • Space
    • HVAC Energy Recovery
    • Defense
    • Medical
    • Data Centers
    • Other
  • Resources
    • Blog
    • Calculators & Selection Tools
      • AAHX Selection Tool
      • Enclosure Cooling Selection Tool
      • Heat Pipe Calculator
      • PCM Calculator
      • WAHX Selection Tool
    • Publications
      • Published Articles
      • Patents
      • Technical Papers
    • Learning Center
      • Heat Pipe Learning Center
      • Pumped Two-Phase Learning Center
      • PCM Learning Center
      • HVAC Learning Center
      • Videos
      • eBooks
      • Brochures
      • Case Studies
      • Webinars
    • Find your Rep
  • Shop
    • Sealed Enclosure Coolers
    • Heat Pipe Coolers
      • Heat Pipe Cooler Accessories
    • Heat Sink Coolers
      • Heat Sink Cooler Accessories
    • Thermoelectric Coolers
    • Vapor Compression Coolers
  • About
    • Careers
    • Events
    • News
    • Sustainability
    • ACT Leadership
  • Contact
0
Cart Icon View Cart
  • Heat Pipes
  • Loop Thermosyphon
  • Thermosyphons
  • Phase Change Based Solutions
  • Liquid Cold Plates
Thermal Solutions | Passive Thermal Solutions | Loop Thermosyphon
Loop Thermosyphon

WHAT IS A LOOP THERMOSYPHON?

Loop thermosyphon demonstration

A Loop Thermosyphon (LTS) is an ideal solution for any system that can leverage gravity assist fluid return. LTS are routinely found in Power Electronics applications where customers mount IGBTs and other high-power density devices directly to an evaporator plate and have the ability to remotely locate the condenser or heat sink above the components. ACT systems are fielded in a variety of industries including medical, energy/utility, automation, and HVAC systems.

The principle operation is similar to a heat pipe or thermosyphon where heat generated by components causes liquid within the attached cold plates to evaporate.  The expansion of this fluid as it changes phase from liquid to vapor creates a stirring motion that increases convection and subsequently, heat transfer efficiency. The system takes advantage of the latent heat of the fluid which allows for such high heat transfer rates.

A Loop Thermosyphon can move larger amounts of heat compared to a similar-sized heat pipe or thermosyphon because there is no counterflow (liquid and vapor moving in opposing directions). The “loop” aspect makes this possible by designing a discrete vapor line to the heat sink, condensing within the heatsink, and liquid returning down a separate fluid line.

A loop thermosyphon is a scalable technology, with products built from less than 100W to upward of 75,000W. It’s an ideal choice for electronics and Power Electronics applications because of its passive operation, di-electric working fluid options, and high performance. Geometric design flexibility is also critical to most system engineers. Loop thermosyphons can move heat very large distances and can incorporate important features on the evaporator, condenser and fluid lines to allow for easy integration.

A few past projects tailored to our customer’s needs:

Power Electronics Cooler

  • Industry: Power Conversion
  • Power: 5-15 kW
  • Key Features: Patent-pending evaporator plate to allow for direct mount of multiple IGBTs on both sides. Di-electric fluid for electrical isolation.
EXPLORE POWER ELECTRONICS
Loop Thermosyphon on Nacelle

Wind Turbine Cooling

  • Industry: Wind Energy
  • Power: 75kW
  • Key Features: Replaced a pumped solution, saving millions of dollars in maintenance of 20+ year lifespan, rugged (ice/hail, etc), Liquid-Liquid Heat Exchanger (LLHX) Evaporator Section.
EXPLORE WIND ENERGY

Flexible Line, IGBT Cooler

  • Industry: Industrial Power Electronics
  • Power: 5-15 kW
  • Key Features: Dielectric, flexible coolant lines for remote mounting of condenser. Direct mount, patent-pending custom evaporator design. Multiple condenser configurations available.
EXPLORE IGBTs

Loop Thermosyphon for a Medical Application

  • Power: ~1000W
  • Key Features: All aluminum design; High heat flux evaporator design (~40 W/cm2); eliminating the need for a chiller
EXPLORE MEDICAL

Single IGBT Cooler

  • Application: Solid-state transformer
  • Power: ~1000W
  • Key Features: All Aluminum construction; Patent pending custom evaporator design
EXPLORE POWER ELECTRONICS

HVAC Heat Exchangers

  • Industry HVAC Energy Recovery
  • Power: Scalable > 100kW
  • Configurations:
    • WAHX; AAHX; Split Loop Thermosyphon
EXPLORE HVAC ENERGY RECOVERY
TALK WITH OUR ENGINEERS

Tell us about your project, the more details the better. That way we know which team to get you started with. We will reach out to get a meeting scheduled and get you on your way to solving this thermal challenge.

Contact ACT Today
Top Up facing arrow in a square
Page Index
  1. WHAT IS A LOOP THERMOSYPHON?
  2. A few past projects tailored to our customer's needs:
    1. Power Electronics Cooler
    2. Wind Turbine Cooling
    3. Flexible Line, IGBT Cooler
    4. Loop Thermosyphon for a Medical Application
Related Resources
Article: Active and Passive Systems for Wind Icon for Article: Active and Passive Systems for Wind Heat Pipe Learning Center Icon for Heat Pipe Learning Center Webinar: High Performance Thermal Solutions Icon for Webinar: High Performance Thermal Solutions Loop Thermosyphon Feature Article Icon for Loop Thermosyphon Feature Article High Heat Flux Loop Thermosyphon for Laboratory Measurement Systems Icon for High Heat Flux Loop Thermosyphon for Laboratory Measurement Systems
ACT Quality White arrow in white square Contact ACT White arrow in white square Find your Rep White arrow in white square
ACT Logo
Advanced Cooling Technologies, Inc.
1046 New Holland Avenue
Lancaster, Pennsylvania 17601, USA
(717) 295-6061 Contact Our Experts
linkedin youtube twitter facebook
  • shop products online
  • sitemap
  • privacy policy
  • terms & conditions
  • ISO9001 & AS9100 CERTIFIED, ITAR REGISTERED

Copyright 2025. All rights reserved.